Ambient Viable Andersen Cascade Impactors
Tisch Environmental ambient viable andersen cascade impactors are used for the collection of
airborne aerosols containing bacteria or fungi. These devices come in six stage (TE-10-800), two
stage (TE-10-860), or single stage (TE-10-890) variations with an available pump for sampling at
28.3lpm. These ambient viable impactors are precision-machined out of high-quality aluminium
plates with successively smaller diameter holes. As the ambient air cascades through the different
stages, the corresponding particulates impact on the stage as the smaller particulates continue to
travel through the stages until they are entrapped on the corresponding plate. These viable
bacterial particulates are then incubated and then counted or identified. They can then be recorded
and related to where they may be deposited on the human lung.
Features
- High Sample Flow Rate of 28.3 ALPM
- Size separation from >9µm to <0.3µm.
- Optional volumetric flow controlled vacuum system.
- Corrosion resistant alloy aluminium with silicone seals.
- Time proven virtual elimination of particle bounce and re-entrapment.
- Highest proven collection efficiency, reproducibility and accuracy.
- Incorporates U.S. Federal standards for the “Ideal Cascade Impactor” and meets OSHA, EPA
and ACGIH design requirements for respirable/non respirable fraction.
Part No
1) Tisch TE-10-800X – Six Stage ambient viable sampler system includes 6 Stage Viable impactor
with Silicone O-Rings, Carrying Case, 220V pump
2) Tisch TE-10-830-1 – Six Stage ambient viable impactor only
3) Tisch TE-10-890X – Single Stage (N6) ambient viable system. Includes Single Stage impactor,
Carrying Case & 220V pump
4) Tisch TE-10-880 – Single Stage (N6) ambient viable impactor with Carrying Case Only
5) Tisch TE-10-850 – Two Stage Ambient Viable Sampler System, Excludes case and vacuum pump
assembly
6) Tisch TE-10-860 – Two Stage Ambient Viable Sampler System, includes case and vacuum pump
assembly
System Specification
6 Stage Viable Andersen Cascade Impactors
Model: TE-10-800
Description : 6 Stage Viable Impactor Sampling System
Flow Rate : 28.3 alpm
Particle Size : 0.85 to 10µm and above
Pump : 110 Volt AC or 220 Volt AC
Carrying Case : Heavy Duty, Watertight, Custom Foam Insert
System Includes : 6 Stage Impactor with silicone o-ring gaskets, pump, silicone tubing, Carrying Case
6 Stage Viable Andersen Cascade Impactors
TE-10-830
Description : 6 Stage Viable Impactor with carrying case only
Flow Rate : 28.3 alpm
Particle Size : 0.85 to 10µm and above
Pump : None
Carrying Case : Heavy Duty, Watertight, Custom Foam Insert
System Includes : 6 Stage Impactor with silicone o-ring gaskets, Carrying Case
2 Stage Viable Andersen Cascade Impactors
TE-10-860
Description : 2 Stage Viable Impactor Sampling System
Flow Rate : 28.3 alpm
Particle Size : 0.65 to 7µm and above
Pump : 110 Volt AC or 220 Volt AC
Carrying Case : Heavy Duty, Watertight, Custom Foam Insert
System Includes : 2 Stage Impactor with silicone o-ring gaskets, pump, silicone tubing, Carrying Case
2 Stage Viable Andersen Cascade Impactors
TE-10-850
Description : 2 Stage Viable Impactor Only
Flow Rate : 28.3 alpm
Particle Size : 0.65 to 7µm and above
Pump : None
Carrying Case : None
System Includes : 2 Stage Impactor with silicone o-ring gaskets
Single Stage (N6) Viable Andersen Cascade Impactors
TE-10-890
Description : Single Stage Viable Impactor Sampling System
Flow Rate : 28.3 alpm
Particle Size : 0.65 to 22µm and above
Pump : 110 Volt AC or 220 Volt AC
Carrying Case : Heavy Duty, Watertight, Custom Foam Insert
System Includes : Single Stage Impactor with silicone o-ring gaskets, pump, silicone
tubing, Carrying Case
Single Stage (N6) Viable Andersen Cascade Impactors
TE-10-880
Description : Single Stage Viable Impactor with carrying case only
Flow Rate : 28.3 alpm
Particle Size : 0.65 to 22µm and above
Pump : None
Carrying Case : Heavy Duty, Watertight, Custom Foam Insert
System Includes : Single Stage Impactor with silicone o-ring gaskets, Carrying Case
Viable Impactors Operation Manual