HAGNER SPECIAL LUMINANCE METER L-202

HAGNER SPECIAL LUMINANCE METER L-202

The Hagner Special Luminance Meter, model L-202, is a small, portable and simple but functional instrument,
specially designed for measurement and evaluation of the luminance at road tunnel entrances and their
surroundings. The measuring range is 0 – 200,000 cd/m². The L-202 is used to determine what measuring range
is required for a stationary Tunnel Photo-meter before it is ordered. With a measuring angle of 20º it measures, at
a certain position from the tunnel entrance, the average luminance of the same area as a standard Tunnel
Photometer would do at the same position. The displayed value can be locked by means of a hold button.
The built-in detector is carefully filtered to give a spectral response close to that of the human eye, as defined in
CIE standards.
If required the L-202 can be mounted on a tripod by means of the standard camera thread (¼'') in the chassis.

Specification

Detector : Silicon photodiode, Vλ-filtered
Measuring Range : 0 – 200,000 cd/m²
Accuracy : Better than ±3% (± 1 in the last digit)
Power Supply : 9 volt battery type PP3 alkaline (lifetime = approx 110 hours).
Dimensions : 170 x 130 x 80 mm
Weight : 0.8 kg (1.6 kgs incl carrying case)

 

Part No

1) Hagner Special Luminance Meter Model L-202

Operation

When looking through the eye-piece, the outer circle of the viewing field represents the 20º measuring angle.
Move the slide switch to the range that gives the greatest degree of accuracy. If the instrument displays only a
digit “1” in the lefthand position, the input signal is too strong, and so a higher range should be selected.
The hold button has two positions, hold and release.

Calibration

The instrument is carefully calibrated when delivered. As the light sensitive diode is extremely stable over long
periods of time recalibration every two-three years should, under normal use of the instrument, be sufficient. If
however there is any reason to believe that the instrument is out of calibration, it can be returned to your stockist
or the manufacturer for earlier control checks.

Power Source

The power source is a standard 9V battery. To avoid battery leakage only alkaline batteries should be used. When
the battery charge is running low, the word ”BAT” will appear on the display. The instrument can then be used for
another 10 hours (approx) before replacing the battery is essential.

The spectral sensitivity of the Hagner luminance meter closely relates to the visibility curve of the CIE standard
observer. Instrument data

Hagner Special Luminance Meter Model L-202