The new SV100A is a wireless whole-body vibration exposure meter suitable for whole-body
measurements in accordance with ISO 2631-1. Suitable for taking measurements both on the
seat and seat-back, the device uses the very latest technology and is easy to use. The
instrument is equipped with 4 push buttons and a small OLED display that allows basic
configuration in the field.
The wireless BT communication interface enables current results to be previewed on a
smartphone or tablet using our Assistant Android application.
The smartphone app can also signal an alarm when set vibration limits are exceeded. Our
advanced technology enables the automatic detection of an operator in the workplace. By default
the instrument is configured for seat measurements (in a horizontal direction) but this setting can
be easily changed.
When changing the orientation of the SV 100A to the vertical, the directions of axes and
weighting filters are automatically adjusted in accordance to ISO 2631-1.
The device is equipped with both RMS and RMQ detectors which allows the calculation of Daily
Vibration Exposure A(8) based on RMS and VDV simultaneously. All measurement results are
stored in a large 8GB internal memory which allows continuous recording over long periods. The
standard 2.0 USB interface allows fast data download and is also used for battery recharging.
For advanced users, the SV 100A offers frequency analysis in 1/1 or 1/3 octaves and time signal
recording to wave format in accordance to ISO 2631-5 that is compatible with popular
recalculation software.
The SV 100A is fully configurable with our Supervisor software. It can quickly and easily be setup
for all the weighting filters required by ISO standards for the estimation of the effects of vibration
on health, comfort, perception and motion sickness. The dedicated Whole-Body Vibration
Exposure panel within Supervisor software makes reporting extremely easy.
Part No
1) Svantek Model SV 100A – Whole body Vibration Dosimeter with Bluetooth communication
2) Svantek Model SF 100A_OCT – 1/1 octave analysis option
3) Svantek Model SF 100A_3OCT – 1/1 and 1/3 octave analysis option
4) Svantek Model SF 100A_WAV – Time domain signal recording option
5) Svantek Model SF 100A_Wf – Motion sickness measurement option